GEMSCAB
Home
About Us
Company Profile
Vision
Quality
Sustainability
Product Line
HT XLPE Cables
LT Power & Control Cables
Fire Survival Cables
Industrial Wires & Cables
Building Wires
Instrumentation Cables
Solar Cables
Fire Alarm Cables
EHV Cables
THERMOCOUPLE EXTENSION
Braided Cables
Submersible Cables
HT XLPE Cables
LT Power & Control
Fire Survival Cables
Industrial Cables
Building Wires
Instrumentation Cables
BMS Cables
VFD Cables
EHV Cables
Fire Alarm Cables
Solar Cables
Thermocouple Cables
Braided Cables
Submersible Cables
Mining Cable
Airfield Cable
Library
Clients
Govt. Sector
Pvt. Sector
Certifications
Catalogues
Product Videos
Corporate Videos
Calculators
Cable Size Calculator
Current Rating With Al/Cu Conductor
CSR
Career
Contact Us
Home
About Us
Company Profile
Vision
Quality
Sustainability
Product Line
HT XLPE Cables
LT Power & Control Cables
Fire Survival Cables
Industrial Wires & Cables
Building Wires
Instrumentation Cables
Solar Cables
Fire Alarm Cables
EHV Cables
THERMOCOUPLE EXTENSION
Braided Cables
Submersible Cables
HT XLPE Cables
LT Power & Control
Fire Survival Cables
Industrial Cables
Building Wires
Instrumentation Cables
BMS Cables
VFD Cables
EHV Cables
Fire Alarm Cables
Solar Cables
Thermocouple Cables
Braided Cables
Submersible Cables
Mining Cable
Airfield Cable
Library
Clients
Govt. Sector
Pvt. Sector
Certifications
Catalogues
Product Videos
Corporate Videos
Calculators
Cable Size Calculator
Current Rating With Al/Cu Conductor
CSR
Career
Contact Us
Home
About Us
Company Profile
Vision
Quality
Sustainability
Product Line
HT XLPE Cables
LT Power & Control Cables
Fire Survival Cables
Industrial Wires & Cables
Building Wires
Instrumentation Cables
Solar Cables
Fire Alarm Cables
EHV Cables
THERMOCOUPLE EXTENSION
Braided Cables
Submersible Cables
Library
Clients
Govt. Sector
Pvt. Sector
Certifications
Catalogues
Product Videos
Corporate Videos
Calculators
Cable Size Calculator
Current Rating With Al/Cu Conductor
CSR
Career
Contact Us
X
Cable Size Calculator
Please enable JavaScript in your browser to complete this form.
Motor Output (kW/HP)
0.37 kW / 0.5 HP
0.55 kW / 0.75 HP
0.75 kW / 1 HP
1.1 kW / 1.5 HP
1.5 kW / 2 HP
2.2 kW / 3 HP
3.7 kW / 5 HP
5.5 kW / 7.5 HP
7.5 kW / 10 HP
9.3 kW / 12.5 HP
11 kW / 15 HP
15 kW / 20 HP
18.5 kW / 25 HP
22 kW / 30 HP
26 kW / 35 HP
30 kW / 40 HP
37 kW / 50 HP
45 kW / 60 HP
55 kW / 75 HP
75 kW / 100 HP
90 kW / 125 HP
110 kW / 150 HP
132 kW / 180 HP
143 kW / 192 HP
Motor Output
kW
0.37
HP
0.50
Full Load Current (Amp)
Line
1.00
Phase
0.60
Direct on line Starter
Overload Relay Range
Amp
1.5 - 3
Max. Backup Fuse
Amp
4.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
Recommended Cable
Sq.mm. Al
-
Size Supply Side
Sq.mm. Cu
-
Size Motor Side
Sq.mm. Al
-
Size Motor Side
Sq.mm. Cu
-
Motor Output
kW
0.55
HP
0.75
Full Load Current (Amp)
Line
1.30
Phase
0.76
Direct on line Starter
Overload Relay Range
Amp
1.5 - 3
Max. Backup Fuse
Amp
4.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
Recommended Cable
Sq.mm. Al
-
Size Supply Side
Sq.mm. Cu
-
Size Motor Side
Sq.mm. Al
-
Size Motor Side
Sq.mm. Cu
-
Motor Output
kW
0.75
HP
1
Full Load Current (Amp)
Line
1.90
Phase
1.12
Direct on line Starter
Overload Relay Range
Amp
1.5 - 3
Max. Backup Fuse
Amp
6.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
Recommended Cable
Sq.mm. Al
-
Size Supply Side
Sq.mm. Cu
-
Size Motor Side
Sq.mm. Al
-
Size Motor Side
Sq.mm. Cu
-
Motor Output
kW
1.1
HP
1.5
Full Load Current (Amp)
Line
2.60
Phase
1.53
Direct on line Starter
Overload Relay Range
Amp
2 - 4
Max. Backup Fuse
Amp
6.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
Recommended Cable
Sq.mm. Al
-
Size Supply Side
Sq.mm. Cu
-
Size Motor Side
Sq.mm. Al
-
Size Motor Side
Sq.mm. Cu
-
Motor Output
kW
1.5
HP
2
Full Load Current (Amp)
Line
3.70
Phase
2.20
Direct on line Starter
Overload Relay Range
Amp
3 - 6
Max. Backup Fuse
Amp
10.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
Recommended Cable
Sq.mm. Al
-
Size Supply Side
Sq.mm. Cu
-
Size Motor Side
Sq.mm. Al
-
Size Motor Side
Sq.mm. Cu
-
Motor Output
kW
2.2
HP
3
Full Load Current (Amp)
Line
4.80
Phase
2.80
Direct on line Starter
Overload Relay Range
Amp
4 - 8
Max. Backup Fuse
Amp
10.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
2-3
Max. Backup Fuse
Amp
6.00
Recommended Cable
Sq.mm. Al
2.50
Size Supply Side
Sq.mm. Cu
1.50
Size Motor Side
Sq.mm. Al
2.50
Size Motor Side
Sq.mm. Cu
1.50
Motor Output
kW
3.7
HP
5
Full Load Current (Amp)
Line
7.80
Phase
4.50
Direct on line Starter
Overload Relay Range
Amp
6 - 12
Max. Backup Fuse
Amp
20.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
4 - 6
Max. Backup Fuse
Amp
10.00
Recommended Cable
Sq.mm. Al
2.50
Size Supply Side
Sq.mm. Cu
1.50
Size Motor Side
Sq.mm. Al
2.50
Size Motor Side
Sq.mm. Cu
1.50
Motor Output
kW
5.5
HP
7.5
Full Load Current (Amp)
Line
11.20
Phase
6.50
Direct on line Starter
Overload Relay Range
Amp
6 - 12
Max. Backup Fuse
Amp
20.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
5.5-8
Max. Backup Fuse
Amp
16.00
Recommended Cable
Sq.mm. Al
2.50
Size Supply Side
Sq.mm. Cu
1.50
Size Motor Side
Sq.mm. Al
2.50
Size Motor Side
Sq.mm. Cu
1.50
Motor Output
kW
7.5
HP
10
Full Load Current (Amp)
Line
16.00
Phase
9.20
Direct on line Starter
Overload Relay Range
Amp
10-16
Max. Backup Fuse
Amp
25.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
2.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
8 - 12
Max. Backup Fuse
Amp
20.00
Recommended Cable
Sq.mm. Al
2.50
Size Supply Side
Sq.mm. Cu
2.50
Size Motor Side
Sq.mm. Al
2.50
Size Motor Side
Sq.mm. Cu
1.50
Motor Output
kW
9.3
HP
12.5
Full Load Current (Amp)
Line
19.00
Phase
11.00
Direct on line Starter
Overload Relay Range
Amp
14 - 20
Max. Backup Fuse
Amp
32.00
(415V)
Recommended Cable
Sq.mm. Al
4.00
(3 Ph)
Size
Sq.mm. Cu
2.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
8 - 12
Max. Backup Fuse
Amp
25.00
Recommended Cable
Sq.mm. Al
4.00
Size Supply Side
Sq.mm. Cu
2.50
Size Motor Side
Sq.mm. Al
2.50
Size Motor Side
Sq.mm. Cu
1.50
Motor Output
kW
11
HP
15
Full Load Current (Amp)
Line
22.00
Phase
12.70
Direct on line Starter
Overload Relay Range
Amp
18 - 24
Max. Backup Fuse
Amp
50.00
(415V)
Recommended Cable
Sq.mm. Al
6.00
(3 Ph)
Size
Sq.mm. Cu
4.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
10 -16
Max. Backup Fuse
Amp
25.00
Recommended Cable
Sq.mm. Al
6.00
Size Supply Side
Sq.mm. Cu
4.00
Size Motor Side
Sq.mm. Al
2.50
Size Motor Side
Sq.mm. Cu
1.50
Motor Output
kW
15
HP
20
Full Load Current (Amp)
Line
29.00
Phase
16.80
Direct on line Starter
Overload Relay Range
Amp
22 - 32
Max. Backup Fuse
Amp
50.00
(415V)
Recommended Cable
Sq.mm. Al
10.00
(3 Ph)
Size
Sq.mm. Cu
6.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
14 - 20
Max. Backup Fuse
Amp
32.00
Recommended Cable
Sq.mm. Al
10.00
Size Supply Side
Sq.mm. Cu
6.00
Size Motor Side
Sq.mm. Al
4.00
Size Motor Side
Sq.mm. Cu
2.50
Motor Output
kW
18.5
HP
25
Full Load Current (Amp)
Line
34.00
Phase
19.70
Direct on line Starter
Overload Relay Range
Amp
25 - 40
Max. Backup Fuse
Amp
63.00
(415V)
Recommended Cable
Sq.mm. Al
16.00
(3 Ph)
Size
Sq.mm. Cu
10.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
18 - 24
Max. Backup Fuse
Amp
50.00
Recommended Cable
Sq.mm. Al
16.00
Size Supply Side
Sq.mm. Cu
10.00
Size Motor Side
Sq.mm. Al
6.00
Size Motor Side
Sq.mm. Cu
4.00
Motor Output
kW
22
HP
30
Full Load Current (Amp)
Line
41.00
Phase
23.70
Direct on line Starter
Overload Relay Range
Amp
30 - 45
Max. Backup Fuse
Amp
80.00
(415V)
Recommended Cable
Sq.mm. Al
16.00
(3 Ph)
Size
Sq.mm. Cu
16.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
17 - 25
Max. Backup Fuse
Amp
50.00
Recommended Cable
Sq.mm. Al
16.00
Size Supply Side
Sq.mm. Cu
16.00
Size Motor Side
Sq.mm. Al
6.00
Size Motor Side
Sq.mm. Cu
6.00
Motor Output
kW
26
HP
35
Full Load Current (Amp)
Line
47.00
Phase
26.90
Direct on line Starter
Overload Relay Range
Amp
38 - 63
Max. Backup Fuse
Amp
80.00
(415V)
Recommended Cable
Sq.mm. Al
25.00
(3 Ph)
Size
Sq.mm. Cu
16.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
22 - 32
Max. Backup Fuse
Amp
63.00
Recommended Cable
Sq.mm. Al
25.00
Size Supply Side
Sq.mm. Cu
16.00
Size Motor Side
Sq.mm. Al
10.00
Size Motor Side
Sq.mm. Cu
6.00
Motor Output
kW
30
HP
40
Full Load Current (Amp)
Line
54.00
Phase
31.20
Direct on line Starter
Overload Relay Range
Amp
38 - 63
Max. Backup Fuse
Amp
100.00
(415V)
Recommended Cable
Sq.mm. Al
25.00
(3 Ph)
Size
Sq.mm. Cu
16.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
22 - 32
Max. Backup Fuse
Amp
63.00
Recommended Cable
Sq.mm. Al
25.00
Size Supply Side
Sq.mm. Cu
16.00
Size Motor Side
Sq.mm. Al
10.00
Size Motor Side
Sq.mm. Cu
6.00
Motor Output
kW
37
HP
50
Full Load Current (Amp)
Line
67.00
Phase
38.70
Direct on line Starter
Overload Relay Range
Amp
50 - 90
Max. Backup Fuse
Amp
100.00
(415V)
Recommended Cable
Sq.mm. Al
35.00
(3 Ph)
Size
Sq.mm. Cu
25.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
25 - 40
Max. Backup Fuse
Amp
80.00
Recommended Cable
Sq.mm. Al
35.00
Size Supply Side
Sq.mm. Cu
25.00
Size Motor Side
Sq.mm. Al
16.00
Size Motor Side
Sq.mm. Cu
10.00
Motor Output
kW
45
HP
60
Full Load Current (Amp)
Line
80.00
Phase
46.40
Direct on line Starter
Overload Relay Range
Amp
50 - 90
Max. Backup Fuse
Amp
125.00
(415V)
Recommended Cable
Sq.mm. Al
50.00
(3 Ph)
Size
Sq.mm. Cu
35.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
38 - 63
Max. Backup Fuse
Amp
100.00
Recommended Cable
Sq.mm. Al
50.00
Size Supply Side
Sq.mm. Cu
35.00
Size Motor Side
Sq.mm. Al
25.00
Size Motor Side
Sq.mm. Cu
16.00
Motor Output
kW
55
HP
75
Full Load Current (Amp)
Line
97.00
Phase
56.00
Direct on line Starter
Overload Relay Range
Amp
70 - 110
Max. Backup Fuse
Amp
160.00
(415V)
Recommended Cable
Sq.mm. Al
70.00
(3 Ph)
Size
Sq.mm. Cu
50.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
38 - 63
Max. Backup Fuse
Amp
100.00
Recommended Cable
Sq.mm. Al
70.00
Size Supply Side
Sq.mm. Cu
50.00
Size Motor Side
Sq.mm. Al
35.00
Size Motor Side
Sq.mm. Cu
25.00
Motor Output
kW
75
HP
100
Full Load Current (Amp)
Line
131.00
Phase
75.60
Direct on line Starter
Overload Relay Range
Amp
90 - 135
Max. Backup Fuse
Amp
200.00
(415V)
Recommended Cable
Sq.mm. Al
95.00
(3 Ph)
Size
Sq.mm. Cu
70.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
50 - 90
Max. Backup Fuse
Amp
160.00
Recommended Cable
Sq.mm. Al
95.00
Size Supply Side
Sq.mm. Cu
70.00
Size Motor Side
Sq.mm. Al
50.00
Size Motor Side
Sq.mm. Cu
35.00
Motor Output
kW
90
HP
125
Full Load Current (Amp)
Line
157.00
Phase
90.60
Direct on line Starter
Overload Relay Range
Amp
140 - 170
Max. Backup Fuse
Amp
250.00
(415V)
Recommended Cable
Sq.mm. Al
150.00
(3 Ph)
Size
Sq.mm. Cu
95.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
70 - 110
Max. Backup Fuse
Amp
160.00
Recommended Cable
Sq.mm. Al
150.00
Size Supply Side
Sq.mm. Cu
95.00
Size Motor Side
Sq.mm. Al
70.00
Size Motor Side
Sq.mm. Cu
50.00
Motor Output
kW
110
HP
150
Full Load Current (Amp)
Line
191.00
Phase
110.00
Direct on line Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
(415V)
Recommended Cable
Sq.mm. Al
-
(3 Ph)
Size
Sq.mm. Cu
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
70 - 110
Max. Backup Fuse
Amp
200.00
Recommended Cable
Sq.mm. Al
185.00
Size Supply Side
Sq.mm. Cu
150.00
Size Motor Side
Sq.mm. Al
95.00
Size Motor Side
Sq.mm. Cu
70.00
Motor Output
kW
132
HP
180
Full Load Current (Amp)
Line
229.00
Phase
132.20
Direct on line Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
(415V)
Recommended Cable
Sq.mm. Al
-
(3 Ph)
Size
Sq.mm. Cu
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
90 - 135
Max. Backup Fuse
Amp
250.00
Recommended Cable
Sq.mm. Al
240.00
Size Supply Side
Sq.mm. Cu
185.00
Size Motor Side
Sq.mm. Al
120.00
Size Motor Side
Sq.mm. Cu
95.00
Motor Output
kW
143
HP
192
Full Load Current (Amp)
Line
248.00
Phase
143.20
Direct on line Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
(415V)
Recommended Cable
Sq.mm. Al
-
(3 Ph)
Size
Sq.mm. Cu
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
120 - 155
Max. Backup Fuse
Amp
250.00
Recommended Cable
Sq.mm. Al
240.00
Size Supply Side
Sq.mm. Cu
185.00
Size Motor Side
Sq.mm. Al
120.00
Size Motor Side
Sq.mm. Cu
95.00
Submit
Please enable JavaScript in your browser to complete this form.
Motor Output (kW)
0.37 kW / 0.5 HP
0.55 kW / 0.75 HP
0.75 kW / 1 HP
1.1 kW / 1.5 HP
1.5 kW / 2 HP
2.2 kW / 3 HP
3.7 kW / 5 HP
5.5 kW / 7.5 HP
7.5 kW / 10 HP
9.3 kW / 12.5 HP
11 kW / 15 HP
15 kW / 20 HP
18.5 kW / 25 HP
22 kW / 30 HP
26 kW / 35 HP
30 kW / 40 HP
37 kW / 50 HP
45 kW / 60 HP
55 kW / 75 HP
75 kW / 100 HP
90 kW / 125 HP
110 kW / 150 HP
132 kW / 180 HP
143 kW / 192 HP
Motor Output
kW
0.37
HP
0.5
Full Load Current (Amp)
Line
1.00
Phase
0.60
Direct on line Starter
Overload Relay Range
Amp
1.5 - 3
Max. Backup Fuse
Amp
4.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
Recommended Cable
Sq.mm. Al
-
Size Supply Side
Sq.mm. Cu
-
Size Motor Side
Sq.mm. Al
-
Size Motor Side
Sq.mm. Cu
-
Motor Output
kW
0.55
HP
0.75
Full Load Current (Amp)
Line
1.30
Phase
0.76
Direct on line Starter
Overload Relay Range
Amp
1.5 - 3
Max. Backup Fuse
Amp
4.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
Recommended Cable
Sq.mm. Al
-
Size Supply Side
Sq.mm. Cu
-
Size Motor Side
Sq.mm. Al
-
Size Motor Side
Sq.mm. Cu
-
Motor Output
kW
0.75
HP
1
Full Load Current (Amp)
Line
1.90
Phase
1.12
Direct on line Starter
Overload Relay Range
Amp
1.5 - 3
Max. Backup Fuse
Amp
6.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
Recommended Cable
Sq.mm. Al
-
Size Supply Side
Sq.mm. Cu
-
Size Motor Side
Sq.mm. Al
-
Size Motor Side
Sq.mm. Cu
-
Motor Output
kW
1.1
HP
1.5
Full Load Current (Amp)
Line
2.60
Phase
1.53
Direct on line Starter
Overload Relay Range
Amp
2 - 4
Max. Backup Fuse
Amp
6.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
Recommended Cable
Sq.mm. Al
-
Size Supply Side
Sq.mm. Cu
-
Size Motor Side
Sq.mm. Al
-
Size Motor Side
Sq.mm. Cu
-
Motor Output
kW
1.5
HP
2
Full Load Current (Amp)
Line
3.70
Phase
2.20
Direct on line Starter
Overload Relay Range
Amp
3 - 6
Max. Backup Fuse
Amp
10.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
Recommended Cable
Sq.mm. Al
-
Size Supply Side
Sq.mm. Cu
-
Size Motor Side
Sq.mm. Al
-
Size Motor Side
Sq.mm. Cu
-
Motor Output
kW
2.2
HP
3
Full Load Current (Amp)
Line
4.80
Phase
2.80
Direct on line Starter
Overload Relay Range
Amp
4 - 8
Max. Backup Fuse
Amp
10.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
2-3
Max. Backup Fuse
Amp
6.00
Recommended Cable
Sq.mm. Al
2.50
Size Supply Side
Sq.mm. Cu
1.50
Size Motor Side
Sq.mm. Al
2.50
Size Motor Side
Sq.mm. Cu
1.50
Motor Output
kW
3.7
HP
5
Full Load Current (Amp)
Line
7.80
Phase
4.50
Direct on line Starter
Overload Relay Range
Amp
6 - 12
Max. Backup Fuse
Amp
20.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
4 - 6
Max. Backup Fuse
Amp
10.00
Recommended Cable
Sq.mm. Al
2.50
Size Supply Side
Sq.mm. Cu
1.50
Size Motor Side
Sq.mm. Al
2.50
Size Motor Side
Sq.mm. Cu
1.50
Motor Output
kW
5.5
HP
7.5
Full Load Current (Amp)
Line
11.20
Phase
6.50
Direct on line Starter
Overload Relay Range
Amp
6 - 12
Max. Backup Fuse
Amp
20.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
1.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
5.5-8
Max. Backup Fuse
Amp
16.00
Recommended Cable
Sq.mm. Al
2.50
Size Supply Side
Sq.mm. Cu
1.50
Size Motor Side
Sq.mm. Al
2.50
Size Motor Side
Sq.mm. Cu
1.50
Motor Output
kW
7.5
HP
10
Full Load Current (Amp)
Line
16.00
Phase
9.20
Direct on line Starter
Overload Relay Range
Amp
10-16
Max. Backup Fuse
Amp
25.00
(415V)
Recommended Cable
Sq.mm. Al
2.50
(3 Ph)
Size
Sq.mm. Cu
2.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
8 - 12
Max. Backup Fuse
Amp
20.00
Recommended Cable
Sq.mm. Al
2.50
Size Supply Side
Sq.mm. Cu
2.50
Size Motor Side
Sq.mm. Al
2.50
Size Motor Side
Sq.mm. Cu
1.50
Motor Output
kW
9.3
HP
12.5
Full Load Current (Amp)
Line
19.00
Phase
11.00
Direct on line Starter
Overload Relay Range
Amp
14 - 20
Max. Backup Fuse
Amp
32.00
(415V)
Recommended Cable
Sq.mm. Al
4.00
(3 Ph)
Size
Sq.mm. Cu
2.50
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
8 - 12
Max. Backup Fuse
Amp
25.00
Recommended Cable
Sq.mm. Al
4.00
Size Supply Side
Sq.mm. Cu
2.50
Size Motor Side
Sq.mm. Al
2.50
Size Motor Side
Sq.mm. Cu
1.50
Motor Output
kW
11
HP
15
Full Load Current (Amp)
Line
22.00
Phase
12.70
Direct on line Starter
Overload Relay Range
Amp
18 - 24
Max. Backup Fuse
Amp
50.00
(415V)
Recommended Cable
Sq.mm. Al
6.00
(3 Ph)
Size
Sq.mm. Cu
4.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
10 -16
Max. Backup Fuse
Amp
25.00
Recommended Cable
Sq.mm. Al
6.00
Size Supply Side
Sq.mm. Cu
4.00
Size Motor Side
Sq.mm. Al
2.50
Size Motor Side
Sq.mm. Cu
1.50
Motor Output
kW
15
HP
20
Full Load Current (Amp)
Line
29.00
Phase
16.80
Direct on line Starter
Overload Relay Range
Amp
22 - 32
Max. Backup Fuse
Amp
50.00
(415V)
Recommended Cable
Sq.mm. Al
10.00
(3 Ph)
Size
Sq.mm. Cu
6.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
14 - 20
Max. Backup Fuse
Amp
32.00
Recommended Cable
Sq.mm. Al
10.00
Size Supply Side
Sq.mm. Cu
6.00
Size Motor Side
Sq.mm. Al
4.00
Size Motor Side
Sq.mm. Cu
2.50
Motor Output
kW
18.5
HP
25
Full Load Current (Amp)
Line
34.00
Phase
19.70
Direct on line Starter
Overload Relay Range
Amp
25 - 40
Max. Backup Fuse
Amp
63.00
(415V)
Recommended Cable
Sq.mm. Al
16.00
(3 Ph)
Size
Sq.mm. Cu
10.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
18 - 24
Max. Backup Fuse
Amp
50.00
Recommended Cable
Sq.mm. Al
16.00
Size Supply Side
Sq.mm. Cu
10.00
Size Motor Side
Sq.mm. Al
6.00
Size Motor Side
Sq.mm. Cu
4.00
Motor Output
kW
22
HP
30
Full Load Current (Amp)
Line
41.00
Phase
23.70
Direct on line Starter
Overload Relay Range
Amp
30 - 45
Max. Backup Fuse
Amp
80.00
(415V)
Recommended Cable
Sq.mm. Al
16.00
(3 Ph)
Size
Sq.mm. Cu
16.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
17 - 25
Max. Backup Fuse
Amp
50.00
Recommended Cable
Sq.mm. Al
16.00
Size Supply Side
Sq.mm. Cu
16.00
Size Motor Side
Sq.mm. Al
6.00
Size Motor Side
Sq.mm. Cu
6.00
Motor Output
kW
26
HP
35
Full Load Current (Amp)
Line
47.00
Phase
26.90
Direct on line Starter
Overload Relay Range
Amp
38 - 63
Max. Backup Fuse
Amp
80.00
(415V)
Recommended Cable
Sq.mm. Al
25.00
(3 Ph)
Size
Sq.mm. Cu
16.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
22 - 32
Max. Backup Fuse
Amp
63.00
Recommended Cable
Sq.mm. Al
25.00
Size Supply Side
Sq.mm. Cu
16.00
Size Motor Side
Sq.mm. Al
10.00
Size Motor Side
Sq.mm. Cu
6.00
Motor Output
kW
30
HP
40
Full Load Current (Amp)
Line
54.00
Phase
31.20
Direct on line Starter
Overload Relay Range
Amp
38 - 63
Max. Backup Fuse
Amp
100.00
(415V)
Recommended Cable
Sq.mm. Al
25.00
(3 Ph)
Size
Sq.mm. Cu
16.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
22 - 32
Max. Backup Fuse
Amp
63.00
Recommended Cable
Sq.mm. Al
25.00
Size Supply Side
Sq.mm. Cu
16.00
Size Motor Side
Sq.mm. Al
10.00
Size Motor Side
Sq.mm. Cu
6.00
Motor Output
kW
37
HP
50
Full Load Current (Amp)
Line
67.00
Phase
38.70
Direct on line Starter
Overload Relay Range
Amp
50 - 90
Max. Backup Fuse
Amp
100.00
(415V)
Recommended Cable
Sq.mm. Al
35.00
(3 Ph)
Size
Sq.mm. Cu
25.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
25 - 40
Max. Backup Fuse
Amp
80.00
Recommended Cable
Sq.mm. Al
35.00
Size Supply Side
Sq.mm. Cu
25.00
Size Motor Side
Sq.mm. Al
16.00
Size Motor Side
Sq.mm. Cu
10.00
Motor Output
kW
45
HP
60
Full Load Current (Amp)
Line
80.00
Phase
46.40
Direct on line Starter
Overload Relay Range
Amp
50 - 90
Max. Backup Fuse
Amp
125.00
(415V)
Recommended Cable
Sq.mm. Al
50.00
(3 Ph)
Size
Sq.mm. Cu
35.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
38 - 63
Max. Backup Fuse
Amp
100.00
Recommended Cable
Sq.mm. Al
50.00
Size Supply Side
Sq.mm. Cu
35.00
Size Motor Side
Sq.mm. Al
25.00
Size Motor Side
Sq.mm. Cu
16.00
Motor Output
kW
55
HP
75
Full Load Current (Amp)
Line
97.00
Phase
56.00
Direct on line Starter
Overload Relay Range
Amp
70 - 110
Max. Backup Fuse
Amp
160.00
(415V)
Recommended Cable
Sq.mm. Al
70.00
(3 Ph)
Size
Sq.mm. Cu
50.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
38 - 63
Max. Backup Fuse
Amp
100.00
Recommended Cable
Sq.mm. Al
70.00
Size Supply Side
Sq.mm. Cu
50.00
Size Motor Side
Sq.mm. Al
35.00
Size Motor Side
Sq.mm. Cu
25.00
Motor Output
kW
75
HP
100
Full Load Current (Amp)
Line
131.00
Phase
75.60
Direct on line Starter
Overload Relay Range
Amp
90 - 135
Max. Backup Fuse
Amp
200.00
(415V)
Recommended Cable
Sq.mm. Al
95.00
(3 Ph)
Size
Sq.mm. Cu
70.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
50 - 90
Max. Backup Fuse
Amp
160.00
Recommended Cable
Sq.mm. Al
95.00
Size Supply Side
Sq.mm. Cu
70.00
Size Motor Side
Sq.mm. Al
50.00
Size Motor Side
Sq.mm. Cu
35.00
Motor Output
kW
90
HP
125
Full Load Current (Amp)
Line
157.00
Phase
90.60
Direct on line Starter
Overload Relay Range
Amp
140 - 170
Max. Backup Fuse
Amp
250.00
(415V)
Recommended Cable
Sq.mm. Al
150.00
(3 Ph)
Size
Sq.mm. Cu
95.00
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
70 - 110
Max. Backup Fuse
Amp
160.00
Recommended Cable
Sq.mm. Al
150.00
Size Supply Side
Sq.mm. Cu
95.00
Size Motor Side
Sq.mm. Al
70.00
Size Motor Side
Sq.mm. Cu
50.00
Motor Output
kW
110
HP
150
Full Load Current (Amp)
Line
191.00
Phase
110.00
Direct on line Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
(415V)
Recommended Cable
Sq.mm. Al
-
(3 Ph)
Size
Sq.mm. Cu
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
70 - 110
Max. Backup Fuse
Amp
200.00
Recommended Cable
Sq.mm. Al
185.00
Size Supply Side
Sq.mm. Cu
150.00
Size Motor Side
Sq.mm. Al
95.00
Size Motor Side
Sq.mm. Cu
70.00
Motor Output
kW
132
HP
180
Full Load Current (Amp)
Line
229.00
Phase
132.20
Direct on line Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
(415V)
Recommended Cable
Sq.mm. Al
-
(3 Ph)
Size
Sq.mm. Cu
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
90 - 135
Max. Backup Fuse
Amp
250.00
Recommended Cable
Sq.mm. Al
240.00
Size Supply Side
Sq.mm. Cu
185.00
Size Motor Side
Sq.mm. Al
120.00
Size Motor Side
Sq.mm. Cu
95.00
Motor Output
kW
143
HP
192
Full Load Current (Amp)
Line
248.00
Phase
143.20
Direct on line Starter
Overload Relay Range
Amp
-
Max. Backup Fuse
Amp
-
(415V)
Recommended Cable
Sq.mm. Al
-
(3 Ph)
Size
Sq.mm. Cu
(50 Hz)
Star Delta Starter
Overload Relay Range
Amp
120 - 155
Max. Backup Fuse
Amp
250.00
Recommended Cable
Sq.mm. Al
240.00
Size Supply Side
Sq.mm. Cu
185.00
Size Motor Side
Sq.mm. Al
120.00
Size Motor Side
Sq.mm. Cu
95.00
Submit